Bryant Light Commercial Rooftop Units
Bryant® rooftop units include a full range of durable heating and cooling systems for residential and light commercial applications. From single-stage to multi-stage, gas/electric to electric/electric, our rooftop air conditioners, furnaces and heat pumps give you the options you need. If you're looking for comfort you can rely on, look no further.
Select a model below to learn more.
Bryant Legacy™ Line Split Systems
Legacy Line Split Systems offer our full line of factory options or field-installed accessories. Equipped for single- and multi-stage operation, these rooftop units are your answer for commercial building applications. Backed by Bryant® quality, these air conditioners and heat pumps provide years of reliable performance.
Bryant Legacy™ Line Rooftop Series
The Legacy Line Rooftop Series from Bryant is one of the more affordable rooftop units that still pack a powerful heating and cooling punch. Whether you're in the market for a gas heating/electric cooling system, electric heating/electric cooling system, or heat pump system, there is a Legacy Line rooftop unit to fit your needs.

Rooftop Electric Heating/Electric Cooling (551J)
The 551J packaged rooftop air conditioner with electric heat is available in 3 to 25 ton models that are ASHRAE 90.1 energy compliant and Energy Star® certified. These units offer up to 15.6 SEER cooling performance and can be customized with a full line of factory options or field-installed accessories. Single- and multi-stage cooling models are available with a variety of heating sizes for each unit size.
Features
- Seer Rating: Up to 15.6
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Central terminal board
- Perfect Humidity™ system available
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- 5-year limited warranty on electric heat parts
- Extended protection programs available

Rooftop Heat Pump (549J)
Our Preferred packaged rooftop heat pump, the 549J, is available in 3 to 25 ton capacities that are ASHRAE 90.1 energy compliant and Energy Star® certified. These units offer a full line of factory options or field-installed accessories to go along with energy-saving performance of up to 15.8 SEER and up to 8.2 HSPF heating. Single- and multi-stage cooling and heating models are available with a variety of heating sizes for each unit size.
Features
- SEER Rating: Up to 15.8
- HSPF: 8.2
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Central terminal board
- Perfect Humidity™ system available
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- 5-year limited warranty on electric heat parts
- Extended protection programs available

Rooftop Gas Heating/Electric Cooling (581J)
The 581J is available in 3 to 25 ton single packaged rooftops that are ASHRAE 90.1 energy compliant and Energy Star® certified. These gas heating/electric cooling units offer up to 15.6 SEER cooling efficiency and up to 82% AFUE heating performance. Customize them with a full line of factory options or field-installed accessories. Single- and multi-stage cooling and heating models are available with a variety of heating sizes for each unit size.
Features
- SEER Rating: Up to 15.6
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Central terminal board
- Perfect Humidity™ system available
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- 10-year limited warranty on gas heat exchanger parts
- Extended protection programs available

Single-Packaged Rooftop Units, High Efficiency, with Gas Heating/Electric Cooling and Axion™ Technology (581K)
Exclusive, new Axion™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry's first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more - all available on this multi-efficiency offering.
Features
- SEER Rating: Up to 15.6
- Meets and exceeds ASHRAE 90.1 energy efficiency levels
- New unit control board with intuitive, quick fan speed adjustment
- NEW Direct Drive - Axion™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
- Two-stage cooling capacity control on all models
- SEER to 16.0
- Gas efficiencies up to 82%
- Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C)
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving indoor fan motor delay
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

High Efficiency Single-Packaged Rooftop Units with Axion Technology and Electric Heating/Electric Cooling (551K)
Exclusive, new Axion™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry's first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more - all available on this multiefficiency offering.
Features
- SEER Rating: Up to 15.6
- Meets and exceeds ASHRAE 90.1 energy efficiency levels
- New unit control board with intuitive, quick fan speed adjustment
- NEW Direct Drive - Axion™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
- Two-stage cooling capacity control on all models
- SEER to 16.0
- Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C)
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Split System Heat Pump (575J)
The 575J is available in 3 to 20 ton split system heat pumps that are ASHRAE 90.1 energy compliant. They unit offer a full line of factory options or field-installed accessories and can provide single- or multi-stage cooling. Add heating comfort with the matching 524J air handler. A variety of sizes of electric heat is available per unit size.
Features
- Efficiency Up to 11.0 EER / Up to 13.2 IEER / Up to 3.5 COP
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Comfort alert diagnostic controller
- Refrigerant accumulator on each circuit
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- Extended protection programs available

Split System Air Conditioner (569J)
The 569J is available in 3 to 20 ton split system air conditioners that are ASHRAE 90.1 energy compliant. They offer a full line of factory options or field-installed accessories and can provide single- or multi-stage cooling. Add heating comfort with the matching 524J air handler. A variety of sizes of electric heat is available per unit size.
Features
- Efficiency Up to 11.5 EER / Up to 13.2 IEER
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Comfort alert diagnostic controller
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- Extended protection programs available

Packaged Direct Expansion Cooling Only or Heat Pump Air-Handling Unit with Puron® Refrigerant (524J)
The 524J and 569J/575J series indoor air handlers and outdoor units provide a wide variety of options for your HVAC application needs. These units are designed for long dependable operation whether it's a rooftop or on-the-ground installation. All Condensing Units and Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.
Features
- Uses field-supplied Puron® (R-410A) refrigerant and chilled water
- Non-corroding drain pans
- Cleanable insulation treated with an anti-microbial agent
- Fan motor options allowing more complex new or replacement air distribution systems
- Powerful belt-driven forward curved centrifugal fans
- Durable die-formed galvanized steel casings
- Direct expansion cooling coils are rated in accordance with ARI standard 340/360 when paired with 569J or 575J condensing units

Rooftop Gas Heating/Electric Cooling (580J)
The 580J is available in 3 to 25 ton single packaged rooftops that are ASHRAE 90.1 energy compliant. These gas heating/electric cooling units offer 13 SEER cooling efficiency and 82% AFUE heating performance. Customize them with a full line of factory options or field-installed accessories. Single- and multi-stage cooling and heating models are available with a variety of heating sizes for each unit size.
Features
- Efficiency 13.0 SEER / Up to 11.1 EER / Up to 11.8 IEER / Up to 82% AFUE
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Central terminal board
- Perfect Humidity™ system available
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- 10-year limited warranty on gas heat exchanger parts
- Extended protection programs available

Rooftop Electric Heating/Electric Cooling (558J)
The 558J packaged rooftop air conditioner with electric heat is available in 3 to 25 ton models that are ASHRAE 90.1 energy compliant. These units offer a full line of factory options or field-installed accessories to go along with energy-saving performance of 13 SEER cooling. Single- and multi-stage models are available with a variety of heating sizes for each unit size.
Features
- Efficiency 13.0 SEER / Up to 11.3 EER / Up to 11.8 IEER
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Central terminal board
- Perfect Humidity™ system available
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- 5-year limited warranty on electric heat parts
- Extended protection programs available

Rooftop Heat Pump (548J)
Our Legacy packaged rooftop heat pump, the 548J is available in 3 to 25 ton models that are ASHRAE 90.1 energy compliant. These units offer a full line of factory options or field-installed accessories to go with 13.4 SEER cooling efficiency and 7.7 HSPF heating. Single- and multi-stage cooling and heating models are available with a variety of heating sizes for each unit size.
Features
- Efficiency Up to 13.4 SEER / Up to 11.2 EER / Up to 12.2 IEER / Up to 7.7 HSPF / Up to 3.4 COP
- Puron refrigerant
- ASHRAE 62.1 compliant condensate pan
- Vertical or horizontal airflow models
- Fully safety protected
- Scroll compressors internally protected
- Handled access doors
- Central terminal board
- Perfect Humidity™ system available
- 1-year limited warranty on parts
- 5-year limited warranty on compressor parts
- 5-year limited warranty on electric heat parts
- Extended protection programs available

Standard Efficiency Gas Heating/Electric Cooling Rooftop Unit with Axion™ Technology (582K)
Exclusive, new Axion™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry's first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more - all available on this multiefficiency offering.
Features
- Efficiency Up to 14.0 SEER / Up to 15.0 IEER / Up to 82% AFUE
- Meets and exceeds ASHRAE 90.1 energy efficiency levels
- New unit control board with intuitive quick fan speed adjustment
- New direct drive - Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07 models
- SEERs up to 14.0, IEER of 15.0
- Gas efficiencies up to 82%
- Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Exclusive IGC solid-state control for on-board diagnostics with LED error code designation and burner control logic
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Standard Efficiency Electric Heating/Electric Cooling Rooftop Units with Axion™ Technology (559K)
Exclusive, new Axion™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry's first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more - all available on this multiefficiency offering.
Features
- Efficiency Up to 14.0 SEER / Up to 15.2 IEER
- Meets and exceeds ASHRAE 90.1 energy efficiency levels
- New unit control board with intuitive quick fan speed adjustment
- New direct drive - Axion™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07 models
- SEERs up to 14.0, IEER of 15.2
- Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Single-Packaged 14 SEER Standard Efficiency Rooftop Heat Pumps with Puron® Refrigerant (547J)
The 547J rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, "no-strip screw" collars, and handled access panels, we've made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with Puron® (R-410A) refrigerant at the factory. The units are factory tested in cooling mode.
Features
- Efficiency Up to 14.3 SEER / Up to 12.2 EER / Up to 8.2 HSPF
- ASHRAE 90.1 compliant
- Single-stage cooling capacity control
- Up to 14.3 SEER, 12.2 EER and 8.2 HSPF
- Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
- Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Single-Packaged Standard Efficiency 14 SEER Gas Heating/Electric Cooling Rooftop Unit with Puron® Refrigerant (582J)
582J rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, "no-strip screw" collars, and handled access panels, we've made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with Puron® (R-410A) refrigerant at the factory. The units are factory tested in cooling mode.
Features
- Efficiency Up to 14.1 SEER / Up to 12.0 IEER / Up to 82% AFUE
- ASHRAE 90.1 compliant
- Single-stage cooling capacity control
- Up to 14.1 SEER and 12.0 EER
- Gas efficiencies up to 82%
- Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
- Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving indoor fan motor delay
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Standard Efficiency 14 SEER Electric Heating/Electric Cooling Units with Puron® Refrigerant (559J)
559J rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, "no-strip screw" collars, and handled access panels, we've made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with Puron® (R-410A) refrigerant at the factory. The units are factory tested in cooling mode.
Features
- Efficiency Up to 14.1 SEER / Up to 12.0 IEER
- ASHRAE 90.1 compliant
- Single-stage cooling capacity control
- Up to 14.1 SEER and 12.0 EER
- Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
- Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection